Product Description
Hermetic Refrigertion Scroll Compressor ZF18K4E-TFD-551
Refrigerant: R404/R22 50Hz
Med Temperature
Large operating envelope
Fast temperature pull down capabilities
Light weight and compactness
Scroll Digital Technology for simple, step-less capacity modulation
| Model NO. | Cindensate Temperature | The Evaporation Temperature ° C (R22/50HZ) | |||||
| -12 | -10 | -5 | 0 | 5 | 10 | ||
| ZB15KQ | 40 | 3300 | 3550 | 4350 | 5200 | 6250 | 7400 |
| ZB19KQ | 40 | 3650 | 3950 | 4850 | 5850 | 7000 | 8300 |
| ZB21KQ | 40 | 4650 | 5050 | 6200 | 7450 | 8850 | 10500 |
| ZB26KQ | 40 | 5100 | 5500 | 6800 | 8200 | 9850 | 11700 |
| ZB29KQ | 40 | 6230 | 6790 | 8290 | 9970 | 11800 | 14070 |
| ZB38KQ | 40 | 7300 | 8000 | 9950 | 12200 | 14650 | 17300 |
| ZB45KQ | 40 | 9400 | 15710 | 12400 | 14900 | 17800 | 21000 |
| ZB48KQ | 40 | 10390 | 11285 | 13700 | 16436 | 19574 | 23199 |
| ZB58KQ | 40 | 11800 | 12950 | 16100 | 19600 | 19574 | 28000 |
| ZB66KQ | 40 | 13950 | 15100 | 18400 | 22200 | 26500 | 31500 |
| ZB76KQ | 40 | 16400 | 17800 | 21700 | 28500 | 30500 | 35500 |
| ZB88KQ | 40 | 18800 | 20400 | 24900 | 30000 | 36000 | 42000 |
| ZB95KQ | 40 | 19500 | 21400 | 26500 | 32000 | 38200 | 45200 |
| ZB114KQ | 40 | 23200 | 25500 | 31700 | 38500 | 41600 | 54500 |
| Model NO. | Cindensate Temperature | The Evaporation Temperature ° C (R404/50HZ) | ||||||
| -25 | -20 | -15 | -10 | -5 | 0 | 5 | ||
| ZB15KQE | 40 | 1870 | 2430 | 3000 | 3700 | 4450 | 5350 | 6350 |
| ZB19KQE | 40 | 2490 | 3050 | 3750 | 4550 | 5450 | 6500 | 7700 |
| ZB21KQE | 40 | 3000 | 3700 | 4550 | 5000 | 6600 | 7900 | 9350 |
| ZB26KQE | 40 | 3500 | 4300 | 5250 | 6350 | 7650 | 9100 | 10800 |
| ZB29KQE | 40 | 4070 | 5040 | 6160 | 7460 | 8960 | 10680 | 12650 |
| ZB38KQE | 40 | 5100 | 6250 | 7700 | 9300 | 11200 | 13350 | 15800 |
| ZB45KQE | 40 | 6000 | 7400 | 9050 | 10950 | 13150 | 15700 | 18600 |
| ZB48KQE | 40 | 6579 | 8150 | 9969 | 12074 | 14500 | 17287 | 2571 |
| ZB58KQE | 40 | 7050 | 9250 | 11700 | 14400 | 17500 | 21000 | 24900 |
| ZB66KQE | 40 | 8900 | 11100 | 13500 | 16400 | 19600 | 23400 | 27600 |
| ZB76KQE | 40 | 10900 | 13300 | 16100 | 19400 | 23300 | 27800 | 33000 |
| After-sales Service: | Online Support |
|---|---|
| Warranty: | Online Support |
| Lubrication Style: | Lubricated |
| Cooling System: | Air Cooling |
| Cylinder Arrangement: | Balanced Opposed Arrangement |
| Cylinder Position: | Angular |
| Customization: |
Available
|
|
|---|
.webp)
What Is the Role of Heat Exchangers in Scroll Compressor Systems?
Heat exchangers play a crucial role in scroll compressor systems by facilitating the transfer of heat between different fluid streams. They are essential components that contribute to the overall efficiency and performance of HVAC (Heating, Ventilation, and Air Conditioning) systems. Here’s a detailed explanation of the role of heat exchangers in scroll compressor systems:
1. Heat Transfer:
The primary function of heat exchangers is to transfer heat between two fluid streams while keeping them physically separated. In the context of scroll compressor systems, heat exchangers facilitate the transfer of heat between the refrigerant and the air or water in the HVAC system.
2. Evaporator:
One type of heat exchanger commonly used in scroll compressor systems is the evaporator. The evaporator acts as a heat exchanger where the refrigerant absorbs heat from the surrounding air or water, causing it to evaporate and change from a liquid to a gaseous state. This heat absorption process cools the air or water in the HVAC system, providing the desired cooling effect.
3. Condenser:
Another type of heat exchanger in scroll compressor systems is the condenser. The condenser facilitates the transfer of heat from the refrigerant to the ambient air or a separate water loop. As the refrigerant releases heat, it undergoes a phase change from a gaseous state to a liquid state. The condenser helps dissipate the heat extracted from the conditioned space to the surroundings, allowing the refrigerant to be ready for the next cooling cycle.
4. Efficiency and Performance:
Heat exchangers play a vital role in improving the efficiency and performance of scroll compressor systems. By transferring heat effectively, they enable the compressor to operate at optimum conditions, enhancing energy efficiency and reducing power consumption. Efficient heat transfer also contributes to maintaining a stable temperature and humidity level in the conditioned space, ensuring occupant comfort.
5. Air-to-Air and Air-to-Water Systems:
Depending on the specific HVAC system design, heat exchangers in scroll compressor systems can be configured as air-to-air or air-to-water heat exchangers. In air-to-air systems, the heat exchangers transfer heat between the refrigerant and the air circulating within the HVAC system. In air-to-water systems, the heat exchangers enable heat transfer between the refrigerant and a separate water loop, which can be used for various purposes such as radiant floor heating or domestic hot water production.
6. Coils and Fins:
Heat exchangers in scroll compressor systems often consist of coils and fins to maximize the heat transfer surface area. The coils provide a pathway for the fluid flow, while the fins increase the surface area exposed to the air or water, promoting efficient heat exchange. The design and arrangement of the coils and fins are optimized to enhance heat transfer and minimize pressure drop.
Overall, heat exchangers play a critical role in scroll compressor systems by facilitating heat transfer between the refrigerant and the air or water in the HVAC system. They contribute to the efficiency, performance, and comfort provided by the system, allowing for effective cooling and heating operations.
.webp)
Can Scroll Compressors Be Used for Refrigeration?
Yes, scroll compressors can be used for refrigeration applications. Here’s a detailed explanation:
Scroll compressors are widely used in various refrigeration systems due to their efficiency, reliability, and compact design. They are particularly suited for applications that require consistent cooling or freezing temperatures, such as commercial refrigeration, air conditioning, and heat pump systems.
Here are some key reasons why scroll compressors are suitable for refrigeration:
1. Efficiency: Scroll compressors are known for their high energy efficiency. They typically have a higher coefficient of performance (COP) compared to other compressor types, meaning they can deliver more cooling or heating output per unit of energy consumed. This efficiency can result in reduced energy consumption and operational costs for refrigeration systems.
2. Reliability: Scroll compressors have a simple design with fewer moving parts compared to reciprocating compressors. This simplicity contributes to their reliability and durability. Scroll compressors are less prone to mechanical failures and have longer service life, making them a dependable choice for refrigeration applications.
3. Quiet Operation: Scroll compressors operate at lower noise levels compared to reciprocating compressors. The scroll design minimizes pulsations and vibrations, resulting in smoother and quieter operation. This makes scroll compressors suitable for refrigeration systems used in noise-sensitive environments such as residential areas or commercial spaces.
4. Compact Size: Scroll compressors have a compact and lightweight construction. Their small footprint allows for flexible installation in space-constrained environments, making them ideal for refrigeration systems in commercial refrigerators, display cases, walk-in freezers, and other compact cooling applications.
5. Oil-Free Operation: Some scroll compressors are designed for oil-free operation. Oil-free scroll compressors eliminate the need for oil lubrication, reducing the risk of oil contamination in the refrigeration system. This feature is particularly beneficial in applications where oil presence can be problematic, such as food processing, pharmaceutical storage, or sensitive laboratory environments.
6. Capacity Modulation: Scroll compressors can modulate their capacity to match the cooling load requirements of the refrigeration system. This modulation capability allows for precise temperature control and efficient operation, especially in applications with varying cooling demands. It helps optimize energy consumption and ensures stable and consistent refrigeration performance.
7. Environmental Considerations: Scroll compressors offer environmentally friendly refrigeration solutions. Many scroll compressors are designed to be compatible with low-global warming potential (GWP) refrigerants, such as hydrofluoroolefins (HFOs) or hydrofluorocarbons (HFCs) with lower GWP values. This helps reduce the environmental impact of the refrigeration system and supports compliance with regulations and sustainability initiatives.
In summary, scroll compressors are well-suited for refrigeration applications due to their efficiency, reliability, quiet operation, compact size, capacity modulation capabilities, and environmental considerations. They are widely used in various commercial and industrial refrigeration systems, providing effective and energy-efficient cooling solutions.
.webp)
Can Scroll Compressors Handle High-Pressure Applications?
Scroll compressors are capable of handling high-pressure applications, but there are certain considerations to keep in mind. Here’s a detailed explanation:
1. Pressure Ratings:
Scroll compressors are designed to operate within specific pressure ratings. The maximum pressure handling capacity of a scroll compressor is determined by its construction, materials, and design specifications. Manufacturers provide pressure ratings for their scroll compressors, indicating the maximum pressure at which the compressor can safely and reliably operate. It’s important to select a scroll compressor with a pressure rating suitable for the intended high-pressure application.
2. System Design:
The overall system design plays a crucial role in handling high-pressure applications. The components connected to the scroll compressor, such as the condenser, evaporator, and piping, should also be designed and rated to withstand the high pressures. Proper sizing, selection, and installation of these components are essential to ensure the safe and efficient operation of the entire system.
3. Refrigerant Type:
The choice of refrigerant used in the high-pressure application can impact the suitability of scroll compressors. Different refrigerants have varying pressure requirements and properties. It’s important to ensure that the scroll compressor is compatible with the specific refrigerant being used in the high-pressure system.
4. Cooling and Lubrication:
High-pressure applications can generate more heat, which may require enhanced cooling measures. Proper cooling mechanisms, such as fans or additional heat exchangers, should be incorporated into the system design to maintain the compressor’s operating temperature within acceptable limits. Additionally, adequate lubrication is crucial to minimize friction and wear at higher pressures. Ensuring the proper lubrication system is in place is essential for the reliable operation of scroll compressors in high-pressure applications.
5. Manufacturer Guidelines:
It’s important to consult the manufacturer’s guidelines and documentation for specific recommendations regarding the use of scroll compressors in high-pressure applications. Manufacturers provide detailed information on the maximum pressure ratings, refrigerant compatibility, cooling requirements, lubrication recommendations, and other important considerations specific to their scroll compressor models.
While scroll compressors can handle high-pressure applications, it’s critical to ensure that the compressor is appropriately selected, the system design is suitable, and all necessary precautions are taken to maintain safe and reliable operation. By following manufacturer guidelines and working with experienced HVAC professionals, scroll compressors can effectively handle high-pressure applications while maintaining their performance and longevity.


editor by CX 2023-10-27