Product Description
Oilless High Pressure Rotary Portable Mini Industrial Used Movable Single Max Dental AC Oil Screw Part Parts Piston FreeĀ AirĀ PumpĀ Compressor
OIL-INJECTED FIXED SPEED COMPRESSOR
Ā
| Model | Motor Power kW / hp |
Free Air Delivery m3/min |
Noise Level dB(A) |
Dimension L * W * H mm |
Weight Kg |
|||
| 7barg | 8barg | 10barg | 13barg | |||||
| CWD7 | 7.5 / 10 | 1.3 | 1.2 | 1.0 | 0.8 | 66 | 880*700*920 | 240 |
| CWD11 | 11 / 15 | 1.7 | 1.6 | 1.4 | 1.2 | 68 | 1080*750*1000 | 400 |
| CWD15 | 15 / 20 | 2.5 | 2.3 | 2.1 | 1.9 | 68 | 1080*750*1000 | 420 |
| CWD18 | 18.5 / 25 | 3.2 | 3.0 | 2.7 | 2.4 | 68 | 1280*850*1160 | 550 |
| CWD22 | 22 / 30 | 3.8 | 3.6 | 3.2 | 2.8 | 68 | 1280*850*1160 | 580 |
| CWD30 | 30 / 40 | 5.3 | 5.0 | 4.5 | 4.0 | 68 | 1280*850*1160 | 600 |
| CWD37 | 37 / 50 | 6.8 | 6.2 | 5.6 | 5.0 | 68 | 1400*1000*1290 | 800 |
| CWD45 | 45 / 60 | 8.0 | 7.3 | 7.0 | 5.9 | 72 | 1400*1000*1290 | 850 |
| CWD55 | 55 / 75 | 10.1 | 9.5 | 8.7 | 7.8 | 72 | 1800*1230*1570 | 1660 |
| CWD75 | 75 / 100 | 13.6 | 12.8 | 12.3 | 10.2 | 72 | 1800*1230*1570 | 1800 |
| CWD90 | 90 / 125 | 16.2 | 15.5 | 14.0 | 12.5 | 72 | 1800*1230*1570 | 1900 |
| CWD110 | 110 / 150 | 21.2 | 19.8 | 17.8 | 15.5 | 72 | 2400*1470*1840 | 2500 |
| CWD132 | 132 / 180 | 24.5 | 23.2 | 20.5 | 17.8 | 75 | 2400*1470*1840 | 2700 |
| CWD160 | 160 / 215 | 28.8 | 27.8 | 25.0 | 22.4 | 75 | 2400*1470*1840 | 3000 |
| CWD185 | 185 / 250 | 32.5 | 31.2 | 28.0 | 25.8 | 75 | 3150*1980*2150 | 3500 |
| CWD200 | 200 / 270 | 36.0 | 34.3 | 30.5 | 28.0 | 82 | 3150*1980*2150 | 4000 |
| CWD250 | 250 / 350 | 43.0 | 41.5 | 38.2 | 34.9 | 82 | 3150*1980*2150 | 4500 |
| CWD315 | 315 / 400 | 51.0 | 50.2 | 44.5 | 39.5 | 82 | 3150*1980*2150 | 6000 |
| CWD355 | 355 / 450 | 64.0 | 61.0 | 56.5 | 49.0 | 84 | 3150*1980*2150 | 6500 |
| CWD400 | 400 / 500 | 71.2 | 68.1 | 62.8 | 52.2 | 84 | 3150*1980*2150 | 7200 |
| Model | Motor Power kW / hp |
Free Air Delivery m3/min |
Noise Level dB(A) |
Dimension L * W * H mm |
Weight Kg |
|||
| 7barg | 8barg | 10barg | 13barg | |||||
| CWD7 PM | 7.5 / 10 | 1.3 | 1.2 | 1.0 | 0.8 | 66 | 760*700*920 | 200 |
| CWD11 PM | 11 / 15 | 1.7 | 1.6 | 1.4 | 1.2 | 68 | 980*750*1000 | 350 |
| CWD15 PM | 15 / 20 | 2.5 | 2.3 | 2.1 | 1.9 | 68 | 980*750*1000 | 360 |
| CWD18 PM | 18.5 / 25 | 3.2 | 3.0 | 2.7 | 2.4 | 68 | 1120*850*1160 | 500 |
| CWD22 PM | 22 / 30 | 3.8 | 3.6 | 3.2 | 2.8 | 68 | 1120*850*1160 | 520 |
| CWD30 PM | 30 / 40 | 5.3 | 5.0 | 4.5 | 4.0 | 68 | 1120*850*1160 | 550 |
| CWD37 PM | 37 / 50 | 6.8 | 6.2 | 5.6 | 5.0 | 68 | 1280*1000*1290 | 750 |
| CWD45 PM | 45 / 60 | 8.0 | 7.3 | 7.0 | 5.9 | 72 | 1280*1000*1290 | 780 |
| CWD55 PM | 55 / 75 | 10.1 | 9.5 | 8.7 | 7.8 | 72 | 1800*1230*1570 | 1600 |
| CWD75 PM | 75 / 100 | 13.6 | 12.8 | 12.3 | 10.2 | 72 | 1800*1230*1570 | 1800 |
| CWD90 PM | 90 / 125 | 16.2 | 15.5 | 14.0 | 12.5 | 72 | 1800*1230*1570 | 1900 |
| CWD110 PM | 110 / 150 | 21.2 | 19.8 | 17.8 | 15.5 | 72 | 2400*1470*1840 | 2500 |
| CWD132 PM | 132 / 180 | 24.5 | 23.2 | 20.5 | 17.8 | 75 | 2400*1470*1840 | 2700 |
| CWD160 PM | 160 / 215 | 28.8 | 27.8 | 25.0 | 22.4 | 75 | 2400*1470*1840 | 3000 |
| CWD185 PM | 185 / 250 | 32.5 | 31.2 | 28.0 | 25.8 | 75 | 3150*1980*2150 | 3500 |
| CWD200 PM | 200 / 270 | 36.0 | 34.3 | 30.5 | 28.0 | 82 | 3150*1980*2150 | 4000 |
| CWD250 PM | 250 / 350 | 43.0 | 41.5 | 38.2 | 34.9 | 82 | 3150*1980*2150 | 4500 |
| CWD315 PM | 315 / 400 | 51.0 | 50.2 | 44.5 | 39.5 | 82 | 3150*1980*2150 | 6000 |
| CWD355 PM | 355 / 450 | 64.0 | 61.0 | 56.5 | 49.0 | 84 | 3150*1980*2150 | 6500 |
| CWD400 PM | 400 / 500 | 71.2 | 68.1 | 62.8 | 52.2 | 84 | 3150*1980*2150 | 7200 |
TWO-STAGE OIL-INJECTED COMPRESSOR
Ā
| Model | Motor Power kW / hp |
Free Air Delivery m3/min |
Noise Level dB(A) |
Dimension L * W * H mm |
Weight Kg |
|||
| 7barg | 8barg | 10barg | 13barg | |||||
| CWD15-2S | 15 / 20 | 3.0 | 2.9 | 2.4 | 2.2 | 68 | 1480*850*1180 | 780 |
| CWD18-2S | 18.5 / 25 | 3.6 | 3.5 | 2.9 | 2.5 | 68 | 1480*850*1180 | 800 |
| CWD22-2S | 22 / 30 | 4.2 | 4.1 | 3.5 | 3.2 | 68 | 1480*850*1180 | 820 |
| CWD30-2S | 30 / 40 | 6.5 | 6.4 | 4.9 | 4.2 | 68 | 1720*1110*1480 | 1080 |
| CWD37-2S | 37 / 50 | 7.2 | 7.1 | 6.3 | 5.4 | 68 | 1720*1110*1480 | 1100 |
| CWD45-2S | 45 / 60 | 9.8 | 9.7 | 7.8 | 6.5 | 72 | 1720*1110*1480 | 1120 |
| CWD55-2S | 55 / 75 | 12.8 | 12.5 | 9.6 | 8.6 | 72 | 2100*1350*1720 | 2080 |
| CWD75-2S | 75 / 100 | 17.5 | 16.5 | 12.5 | 11.2 | 72 | 2100*1350*1720 | 2100 |
| CWD90-2S | 90 / 125 | 20.8 | 19.8 | 16.9 | 14.3 | 72 | 2460*1700*1900 | 3280 |
| CWD110-2S | 110 / 150 | 24.5 | 23.5 | 19.7 | 17.6 | 72 | 2460*1700*1900 | 3480 |
| CWD132-2S | 132 / 180 | 30.0 | 28.0 | 23.5 | 19.8 | 75 | 2900*1800*2571 | 3980 |
| CWD160-2S | 160 / 215 | 34.5 | 33.6 | 30.0 | 23.8 | 75 | 2900*1800*2571 | 4280 |
| CWD185-2S | 185 / 250 | 41.0 | 38.4 | 32.5 | 28.6 | 75 | 3800*1980*2150 | 5450 |
| CWD200-2S | 200 / 270 | 44.6 | 43.0 | 38.5 | 32.8 | 82 | 3800*1980*2150 | 5600 |
| CWD220-2S | 220 / 300 | 48.6 | 47.0 | 41.0 | 38.0 | 82 | 3800*1980*2150 | 6500 |
| CWD250-2S | 250 / 350 | 55.0 | 54.0 | 46.0 | 40.0 | 82 | 3800*1980*2150 | 6600 |
- Unit measured according to ISO 1217, Annex C, Edition 4 (2009)
Reference conditions:
-Relative humidity 0%
-Absolute inlet pressure: 1 bar (a) (14.5 psi)
-Intake air temperature: 20°C, 68°F
- Noise level measured according to ISO 2151:2004, operation at max. operating pressure and max. speed; tolerance: ±3 dB(A)
- 2S-Two Stage
FAQ
1. Q: Are you a factory or trading company?
Ā A: We are a factory.Ā Ā
2. Q: What’re your payments ?Ā
Ā Ā A: T/T,Western Union,L/C etc.
Ā 3. Q: What about the package ?
Ā A: Standard export plywood case or carton.
4. Q: How long is the warranty ?
Ā A: According to international standards, products in standard operation is 1 year,except quick-wear part.
5. Q: The use of products have?
Ā Ā A: The pump can suck the peanut, pickles, tomato slurry, red sausage, chocolate, hops and syrup etc.
Ā Ā The pump can suck the paint, pigment, glue and adhesive etc.
Ā The pump can suck various glazed slurries of tile, porcelain, brick and chinaware etc.
Ā The pump can suck various toxin and flammable or volatility liquid etc.
Ā The pump can suck various strong acid, alkali and corrosive liquid etc.
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
| After-sales Service: | Oversea Install Service |
|---|---|
| Warranty: | 3 |
| Lubrication Style: | Lubricated |
| Cooling System: | Air Cooling |
| Power Source: | AC Power |
| Cylinder Position: | Horizontal |
| Customization: |
Available
|
|
|---|
.webp)
Can Oil-Free Scroll Compressors Be Used for Medical Air Supply?
Yes, oil-free scroll compressors can be used for medical air supply. Here’s a detailed explanation:
Medical Air Requirements:
Medical air is a critical utility used in various healthcare facilities, including hospitals, clinics, and dental offices. It is used for various purposes, such as respiratory therapy, anesthesia delivery, surgical tools, and medical gas mixing. Medical air must meet strict quality standards to ensure patient safety and the proper functioning of medical equipment.
Oil-Free Operation:
Oil-free scroll compressors are well-suited for medical air supply due to their inherent design that eliminates the need for lubricating oil in the compression chamber. Traditional compressors often use oil for lubrication and sealing, but the presence of oil in the compressed air can be harmful in medical applications. Oil-free scroll compressors prevent the risk of oil contamination in the compressed air, ensuring the delivery of clean and safe medical air.
Air Purity and Filtration:
In medical air systems, air purity is of utmost importance. Oil-free scroll compressors are typically equipped with advanced filtration systems to remove contaminants, particulates, and microorganisms from the compressed air. These filtration systems include intake air filters, coalescing filters, and particulate filters, as well as activated carbon filters for odor and gas removal. The combination of these filtration components ensures that the medical air meets the required purity standards, as specified by medical gas regulations and guidelines.
Compressed Air Quality Standards:
Medical air supply must comply with specific standards and regulations to ensure its suitability for healthcare applications. Depending on the country or region, these standards may include guidelines from organizations such as the European Pharmacopoeia (Ph. Eur.), the United States Pharmacopeia (USP), or the International Organization for Standardization (ISO). These standards specify the maximum allowable levels of impurities, such as particulate matter, moisture, oil, and microbial contaminants, in medical air. Oil-free scroll compressors, when properly maintained and equipped with appropriate filtration systems, can meet these stringent requirements.
System Redundancy and Backup:
Reliability is critical in medical air supply systems to ensure uninterrupted operation and patient safety. Redundancy and backup measures are often incorporated into the system design to minimize the risk of air supply failure. This can include the use of multiple compressors, backup power sources, and redundant filtration systems. Oil-free scroll compressors can be part of such redundant configurations, providing a reliable and continuous supply of medical air.
Regular Maintenance and Compliance:
Proper maintenance and monitoring are essential for oil-free scroll compressors used in medical air supply. Regular inspections, filter replacements, and adherence to maintenance schedules are necessary to ensure the continued delivery of clean and high-quality medical air. Compliance with applicable regulations, such as periodic air quality testing and documentation of maintenance activities, is also crucial to meet the requirements of healthcare accreditation bodies and regulatory authorities.
In summary, oil-free scroll compressors can be effectively used for medical air supply. Their oil-free operation, advanced filtration systems, and compliance with air quality standards make them suitable for healthcare applications. When properly maintained and integrated into a well-designed medical air system, oil-free scroll compressors contribute to the delivery of clean, reliable, and safe medical air for patient care.
.webp)
How Do You Troubleshoot Common Issues with Oil-Free Scroll Compressor Systems?
When troubleshooting common issues with oil-free scroll compressor systems, it’s important to follow a systematic approach to identify and resolve the problem. Here’s a detailed explanation:
Step 1: Gather Information:
Start by gathering relevant information about the compressor system and the specific issue you are experiencing. This may include the compressor model and specifications, maintenance records, any error codes or warning messages displayed, and a description of the problem and its symptoms.
Step 2: Visual Inspection:
Perform a visual inspection of the compressor system. Look for any obvious signs of damage, leaks, loose connections, or unusual noise or vibrations. Check the air intake and exhaust vents for blockages or obstructions. Inspect the control panel and electrical components for any visible issues.
Step 3: Check Power and Controls:
Ensure that the compressor system is receiving proper power supply and that all electrical connections are secure. Check the control settings and adjust them as needed. Verify that any safety switches or interlocks are properly engaged. Test the system with different control settings to see if the issue persists or changes.
Step 4: Review Maintenance and Service Records:
Review the maintenance and service records of the compressor system. Check if any scheduled maintenance tasks, such as filter replacements or lubricant changes, are overdue. Ensure that the system has been properly serviced according to the manufacturer’s recommendations. Improper maintenance or missed service tasks can contribute to performance issues.
Step 5: Monitor Operating Parameters:
Monitor the operating parameters of the compressor system during normal operation. This may include measuring and recording variables such as discharge pressure, suction pressure, motor current, and temperature. Compare these parameters to the manufacturer’s specifications or known good values to identify any deviations that may indicate a problem.
Step 6: Analyze Error Codes or Alarms:
If the compressor system displays error codes or alarms, consult the system’s documentation or user manual to understand their meaning. Error codes can provide valuable information about the specific nature of the issue. Troubleshoot and address the underlying cause of the error code or alarm according to the manufacturer’s instructions.
Step 7: Inspect and Clean Filters:
Check and clean the air intake filters, oil filters, and any other filtration components in the system. Clogged or dirty filters can restrict airflow and cause performance issues. Follow the manufacturer’s guidelines for filter cleaning or replacement. Ensure that the filters are properly installed after cleaning or replacement.
Step 8: Verify Lubrication System:
If applicable, verify the lubrication system of the compressor. Check the oil level and ensure that it is within the recommended range. Inspect the oil cooler, oil lines, and oil filter for any leaks, blockages, or damage. Ensure that the lubricant used is of the correct type and viscosity specified by the manufacturer.
Step 9: Check Cooling System:
Inspect the cooling system of the compressor, including the air or water cooling components. Make sure that the cooling system is functioning properly and that there are no obstructions or restrictions in the airflow or water flow. Clean any accumulated dirt or debris from the cooling fins or heat exchangers.
Step 10: Consult Manufacturer’s Documentation:
If the issue persists or if you are unable to identify the problem, consult the manufacturer’s documentation, such as the user manual or troubleshooting guide. These resources often provide specific troubleshooting steps and solutions for common issues with the oil-free scroll compressor system. Follow the manufacturer’s recommendations and contact their technical support if necessary.
It’s important to note that troubleshooting and maintenance of oil-free scroll compressor systems may require specialized knowledge and expertise. If you are not familiar with the specific equipment or troubleshooting procedures, it is recommended to consult a qualified technician or contact the manufacturer’s technical support for assistance.
In summary, troubleshooting common issues with oil-free scroll compressor systems involves gathering information, performing visual inspections, checking power and controls, reviewing maintenance records, monitoring operating parameters, analyzing error codes, inspecting and cleaning filters, verifying the lubrication system, checking the cooling system, and consulting the manufacturer’s documentation. Following a systematic approach helps identify and resolve problems effectively.
.webp)
What Industries Commonly Use Oil-Free Scroll Air Compressors?
Oil-free scroll air compressors are utilized across various industries that require clean, reliable, and oil-free compressed air. Here’s a detailed explanation:
- Medical and Healthcare: Oil-free scroll compressors find extensive use in medical and healthcare facilities. They provide clean and contaminant-free compressed air for critical applications such as medical air systems, dental equipment, laboratory instruments, respiratory therapy devices, and surgical tools. The oil-free operation ensures the delivery of high-quality air that meets strict medical standards.
- Pharmaceutical: The pharmaceutical industry requires compressed air for numerous applications, including product manufacturing, packaging, and laboratory operations. Oil-free scroll compressors are preferred in pharmaceutical facilities to ensure that the compressed air remains free from oil contamination, maintaining the integrity of the products and meeting stringent regulatory requirements.
- Food and Beverage: In the food and beverage industry, oil-free scroll compressors are commonly used to provide clean and oil-free compressed air for various processes. They are employed in applications such as pneumatic conveying, packaging, bottling, food processing, and air agitation in fermentation and mixing processes. The oil-free operation prevents any possibility of oil contamination in the food or beverage products.
- Electronics and Semiconductor: The electronics and semiconductor industry has stringent requirements for clean and dry compressed air. Oil-free scroll compressors are utilized in clean room environments and semiconductor manufacturing processes where even small oil particles can cause damage to sensitive electronic components. They are suitable for applications such as chip manufacturing, circuit board assembly, and precision instrumentation.
- Laboratories: Research laboratories, testing facilities, and analytical laboratories often require oil-free compressed air for various instruments and equipment. Oil-free scroll compressors provide the necessary clean and dry air supply without the risk of oil contamination. They are used in applications such as chromatography, mass spectrometry, sample preparation, gas generation, and other laboratory processes.
- Automotive and Aerospace: Oil-free scroll compressors are utilized in automotive and aerospace industries for applications such as painting, coating, pneumatic tools, air suspension systems, and clean air supply for testing and assembly processes. The oil-free operation ensures that the compressed air does not introduce contaminants that could affect the quality or performance of automotive or aerospace components.
- Printing and Packaging: In printing and packaging operations, oil-free scroll compressors are used for tasks such as air knives, pneumatic controls, air cushioning, and product labeling. The clean and oil-free compressed air ensures that the printing or packaging process remains free from oil contamination, maintaining the quality and appearance of the printed materials or packaged products.
- Environmental and Water Treatment: Oil-free scroll compressors play a role in environmental and water treatment applications. They are used for aeration in wastewater treatment plants, air sparging in soil remediation, air supply for ozone generators, and other air-driven processes. The oil-free operation ensures that the compressed air does not introduce any contaminants that could impact the treatment processes or the environment.
These are just a few examples of the industries that commonly utilize oil-free scroll air compressors. Their oil-free operation, clean air delivery, reliability, and low maintenance make them well-suited for applications where high air quality, precision, and compliance with industry standards are essential.


editor by CX 2024-03-28