Product Description
| Type: | Oil Free Scroll Air Compressor |
| Voltage: | 380V/50HZ/3P, 220V/60HZ/3P, 400V/50HZ/3P, 415V/50HZ/3P orĀ Customerā²s Requirements |
| Working Pressure: | 8~10bar |
| Installed Motor Power: | 3.0-50Ā Kw |
| Color: | Blue,white |
| Driven Method: | BeltĀ Driven |
| Transport Package: | Standard Wooden Packing |
| application: | Dentistry,Laboratory,New Energy |
Product Features
1.High quanlity oild free compressed air.
2.High efficiency oil free scroll airend.
3.Low Energy Consumption,Low running,maintenance cost.
4.Aptitude and intelligent Control, integrated touch-screen PLC displayer.
5.Unique safe units make whole compressor more safety, more stable,lest noise,lest energy Loss.
6.Easy to install,operate,maintain.
Ā Ā Ā Ā Ā Ā Ā
| Model | Capacity | Pressure | Motor power | QTY of air endĀ | QTY of motor | Noise Level | Diemensions | Weight | Diameter of air outlet pipe | Inner air tank | Outside air tank | |
| Ā | m3/min | Mpa | kW | hp | PCS | PCS | dB(A) | mm | KGS | inch | L | L |
| D04/08-A1 | 0.3 | 0.8 | 3.0 | 4.0 | 04*1 | 1 | 55±2 | 760*690*820 | 200 |  3/4 | 5    | / |
| D04/08-A4 | 0.4/0.3 | 0.8/1.0 | 3.7 | 5 | 04*1 | 1 | 55±2 | 760*690*820 | 200 |  3/4 | 5    | / |
| D04/08-J3 | 0.4/0.3 | 0.8/1.0 | 3.7 | 5 | 04*1 | 1 | 55±2 | 1400*780*1485 | 450 |  3/4 | / | 200    |
| Q08/08-S1 | 0.8 | 0.8 | 7.5 | 10 | 04*2 | 2 | 60±2 | 1400*700*1200 | 400 | 1 1/2 | 24    | / |
| Q08/08-S1 | 0.8 | 0.8 | 7.5 | 10 | 04*2 | 2 | 60±2 | 1400*780*1485 | 450 | 1 1/2 |  | / |
| D06/08-A4 | 0.6/0.4 | 0.8/1.0 | 5.5 | 7 | 0.6*1 | 1 | 55±2 | 760*690*820 | 200 |  3/4 | 5    | / |
| D06/08-J3 | 0.6/0.4 | 0.8/1.0 | 5.5 | 7 | 0.6*1 | 1 | 55±2 | 1400*780*1485 | 450 |  3/4 | / | 200    |
| Z12/08-S1 | 1.2/0.8 | 0.8/1.0 | 11 | 15 | 0.6*2 | 2 | 60±2 | 1400*700*1200 | 350 | 1 1/2 | 24    | / |
| D06/08-J5 | 0.6 | 0.8 | 5.5 | 7 | 0.6*1 | 1 | 60±2 | 1400*780*1485 | 450 | 1 1/2 |  | / |
| Z12/08-J5 | 1.2 | 0.8 | 11 | 15 | 0.6*2 | 2 | 60±2 | 1400*780*1485 | 500 | 1 1/2 |  | / |
| Z18/08-S1 | 1.8/1.5 | 0.8/1.0 | 16.5 | 22 | 0.6*3 | 3 | 62±2 | 1400*700*1670 | 500 | 1 1/2 | 24    | / |
| Z24/08-S1 | 2.4/2.0 | 0.8/1.0 | 22 | 30 | 0.6*4 | 4 | 65±2 | 1400*1550*1200 | 800 | 1 1/2 | 24*2 | / |
| Z30/08-S1 | 3.0/2.4 | 0.8/1.0 | 27.5 | 37 | 0.6*5 | 5 | 65±2 | 1400*1550*1670 | 1080 | 1 1/2 | / | / |
| Z36/08-S1 | 3.6/3.0 | 0.8/1.0 | 33 | 45 | 0.6*6 | 6 | 65±2 | 1400*1550*1670 | 1200 | 1 1/2 | / | / |
| Z42/08-S1 | 4.2/3.6 | 0.8/1.0 | 38.5 | 52 | 0.6*7 | 7 | 65±2 | 2220*1450*1740 | 1400 | 1 1/2 | / | / |
| Z48/08-S1 | 4.8/4.0 | 0.8/1.0 | 44 | 59 | 0.6*8 | 8 | 65±2 | 2220*1450*1750 | 1520 | 1 1/2 | / | / |
| Z54/08-S1 | 5.4/4.5 | 0.8/1.0 | 49.5 | 67 | 0.6*9 | 9 | 65±2 | 2220*1450*1750 | 1650 | 1 1/2 | / | / |
Q1:Ā What is the rotor speed for the air end?
A1:Ā 2980rmp.
Q2:Ā What’sĀ yourĀ leadĀ time?
A2:Ā usually, 5-7Ā days.Ā (OEM orders: 15days)
Q3: Can you offerĀ water cooledĀ air compressor?
A3:Ā Yes, we canĀ (normally, air cooled type).
Q4:Ā What’sĀ theĀ paymentĀ term?
A4:Ā T/T,Ā L/C,Ā WesternĀ Union,Ā etc.Ā AlsoĀ weĀ couldĀ acceptĀ USD,Ā RMB,Ā andĀ otherĀ currency.
Q5:Ā DoĀ youĀ acceptĀ customizedĀ voltage?
A5:Ā Yes.Ā 380V/50Hz/3ph, 380V/60Hz/3ph,Ā 220V/50Hz/3ph, 220V/60Hz/3ph,Ā 440V/50Hz/3ph, 440V/60Hz/3ph,Ā orĀ asĀ perĀ yourĀ requests.
Q6: What is your warranty forĀ air compressor?
A6:Ā One yearĀ for the whole air compressor(not including the consumption spare parts)Ā andĀ technical supportsĀ can be provided according to your needs.
Q7: Can you accept OEM orders?
A7: Yes,Ā OEM orders areĀ warmlyĀ welcome.
Q8:Ā HowĀ aboutĀ yourĀ customerĀ serviceĀ andĀ after-salesĀ service?
A8:Ā 24hrsĀ on-lineĀ support,Ā 48hrsĀ problemĀ solvedĀ promise.
Q9:Ā DoĀ youĀ haveĀ spareĀ partsĀ inĀ stock?
A9:Ā Yes, we do.
Q10:Ā WhatĀ kind ofĀ initial lubricationĀ oil you usedĀ in air compressor?
A10: TOTALĀ 46#Ā mineral oil.
| Product Name: | Oil Free Scroll Air Compressor |
|---|---|
| Motor Power: | 16.5kw/22HP |
| Qty of Air End: | 3 |
| Configuration: | Stationary |
| Noise Level: | Silent |
| Inner Air Tank: | 24 L |
| Customization: |
Available
|
|
|---|
.webp)
What Maintenance Is Required for Oil-Free Scroll Air Compressors?
Maintenance for oil-free scroll air compressors is relatively straightforward. Here’s a detailed explanation:
Regular Inspection:
Perform regular visual inspections of the compressor to check for any signs of damage, leaks, or abnormal operating conditions. Inspect the air filters to ensure they are clean and free from debris that could restrict airflow. Additionally, inspect the electrical connections and controls to ensure they are secure and functioning properly.
Air Filter Maintenance:
Clean or replace the air filters on a regular basis. The frequency of filter maintenance will depend on the operating conditions and the level of airborne contaminants present in the environment. Clogged or dirty filters can restrict airflow and reduce the compressor’s performance. Follow the manufacturer’s guidelines for proper filter maintenance and replacement intervals.
Condensate Drains:
Oil-free scroll compressors typically have condensate drains to remove moisture that accumulates in the compressed air. Regularly inspect and clean the condensate drains to ensure they are free from blockages. Proper functioning of the condensate drains helps maintain the quality of the compressed air and prevents moisture-related issues in downstream equipment.
Belt Tension and Alignment:
If the compressor is belt-driven, check the belt tension and alignment regularly. Improper tension or misalignment can cause excessive wear, reduce efficiency, and potentially lead to belt failure. Follow the manufacturer’s guidelines for proper belt tensioning and alignment procedures.
Vibration and Noise Monitoring:
Monitor the compressor for excessive vibration or unusual noise during operation. Excessive vibration may indicate misalignment, loose components, or worn bearings. Unusual noise can be a sign of mechanical issues. If abnormal vibrations or noises are detected, it is important to investigate and address the underlying causes to prevent further damage and ensure reliable operation.
Professional Servicing:
While oil-free scroll compressors generally have lower maintenance requirements compared to oil-lubricated compressors, it is still recommended to schedule periodic professional servicing. Professional servicing may include tasks such as checking and adjusting compressor settings, lubricating non-contacting parts (if applicable), verifying performance, and conducting more in-depth inspections. Follow the manufacturer’s recommendations for the frequency of professional servicing.
Documentation and Record-Keeping:
Maintain a record of maintenance activities, including inspection dates, filter changes, servicing performed, and any repairs or replacements. This documentation helps track the compressor’s maintenance history, identify recurring issues, and ensure that maintenance tasks are performed at appropriate intervals.
It is important to note that maintenance requirements may vary among different models and manufacturers. Always refer to the specific maintenance guidelines provided by the compressor manufacturer to ensure proper maintenance practices and maximize the longevity and performance of the oil-free scroll air compressor.
.webp)
Are There Regulations Governing the Use of Oil-Free Scroll Air Compressors?
Yes, there are regulations governing the use of oil-free scroll air compressors. Here’s a detailed explanation:
Compressor Regulations:
Oil-free scroll air compressors are subject to various regulations and standards that ensure their safe and proper use. These regulations aim to protect the environment, promote energy efficiency, and ensure the reliability and performance of the compressor systems.
Environmental Regulations:
In many regions, there are environmental regulations that govern the use of air compressors, including oil-free scroll compressors. These regulations focus on minimizing air pollution and reducing the release of harmful substances into the atmosphere. They may specify emission limits for pollutants such as particulate matter, volatile organic compounds (VOCs), and nitrogen oxides (NOx). Compliance with these regulations often requires the use of emission control technologies, such as catalytic converters or filtration systems, to reduce the environmental impact of the compressor operation.
Energy Efficiency Standards:
Energy efficiency is an important consideration in compressor systems, as they consume a significant amount of electrical energy. Many countries and regions have established energy efficiency standards and labeling programs for various types of equipment, including air compressors. These standards set minimum efficiency requirements that oil-free scroll compressors must meet to be considered energy-efficient. Compliance with these standards helps promote the use of more efficient compressor technologies and reduces energy consumption and greenhouse gas emissions.
Industry Standards and Guidelines:
There are also industry-specific standards and guidelines that provide recommendations and best practices for the use of oil-free scroll air compressors. These standards are often developed by organizations such as the International Organization for Standardization (ISO) or industry associations. They cover aspects such as compressor design, performance, safety, maintenance, and testing procedures. Adhering to these standards helps ensure that oil-free scroll compressors are used correctly and that their performance and reliability are optimized.
Occupational Health and Safety Regulations:
Occupational health and safety regulations play a crucial role in governing the use of all types of equipment, including air compressors. These regulations aim to protect workers and ensure a safe working environment. They may address aspects such as equipment installation, electrical safety, noise levels, ventilation requirements, and the use of personal protective equipment (PPE). Compliance with these regulations is essential to prevent accidents, injuries, and occupational health hazards associated with operating oil-free scroll compressors.
Compliance and Certification:
Manufacturers of oil-free scroll air compressors may be required to comply with certification and compliance programs to demonstrate that their products meet the relevant regulations and standards. These programs often involve testing and evaluation of the compressor’s performance, safety features, and environmental impact. Compliance with these programs is typically indicated by certification marks or labels that assure customers and regulatory authorities that the compressors meet the necessary requirements.
It is important for users of oil-free scroll air compressors to be aware of the applicable regulations in their specific region or industry. They should ensure that the compressors they purchase and operate comply with the relevant standards and meet the necessary environmental, energy efficiency, safety, and performance requirements.
In summary, there are regulations governing the use of oil-free scroll air compressors. These regulations cover various aspects, including environmental impact, energy efficiency, industry standards, and occupational health and safety. Compliance with these regulations helps ensure the safe, efficient, and environmentally responsible use of oil-free scroll compressors.
.webp)
Can Oil-Free Scroll Compressors Be Used in Sensitive Applications?
Yes, oil-free scroll compressors are well-suited for sensitive applications that require clean and contaminant-free compressed air. Here’s a detailed explanation:
Oil-Free Operation:
An oil-free scroll compressor operates without the use of lubricating oil, which eliminates the risk of oil contamination in the compressed air. This makes it an ideal choice for sensitive applications that demand high air quality standards and where oil contamination could be detrimental. Industries such as medical, pharmaceutical, laboratory, food processing, electronics manufacturing, and clean room environments can benefit greatly from the oil-free operation of scroll compressors.
Clean Air Requirements:
Sensitive applications often require compressed air that is free from oil particles, moisture, and other contaminants. Oil-free scroll compressors provide clean and uncontaminated compressed air, ensuring that the air quality standards are met. The absence of lubricating oil in the compression process eliminates the possibility of oil carryover, ensuring that the compressed air remains oil-free.
Low Particulate Emissions:
Oil-free scroll compressors are designed to minimize the emission of particulates into the compressed air. The scroll mechanism operates with precision tolerances and smooth surfaces, reducing the generation of particulates during compression. This is especially important in applications where even small amounts of particulates can cause contamination or damage to sensitive equipment or products.
No Oil Carryover:
Oil carryover refers to the presence of oil in the compressed air that can be carried downstream and affect the performance of sensitive equipment or processes. Oil-free scroll compressors eliminate the risk of oil carryover, as there is no lubricating oil used in the compression process. This ensures that the compressed air remains free from oil contaminants and suitable for sensitive applications that require a clean and dry air supply.
Quiet Operation:
Oil-free scroll compressors are known for their quiet operation. The absence of reciprocating parts and reduced vibrations contribute to lower noise levels compared to other compressor types. This makes oil-free scroll compressors suitable for sensitive applications where noise reduction is desired, such as in medical environments, research laboratories, or noise-sensitive manufacturing processes.
Overall, oil-free scroll compressors can be successfully used in sensitive applications that require clean, dry, and contaminant-free compressed air. Their oil-free operation, low particulate emissions, absence of oil carryover, and quiet operation make them an excellent choice for industries and processes that demand high air quality and reliability.


editor by CX 2023-11-09