Product Description
Ā
Ā
Ā
| R22 50HZĀ | SPEC. | |||||
| Model | Power(HP) | Displacement(m³/h) | ARI | Weight(KG) | Height(MM) (Including shock-absorbing strap) | |
| Capacity(W) | Input Power(W) | |||||
| One-Phase(220V-240V) | ||||||
| ZR28K3-PFJ | 2.33 | 6.83 | 6900 | 2520 | 26 | 383 |
| ZR34K3-PFJ | 2.83 | 8.02 | 8200 | 2540 | 29 | 406 |
| ZR34KH-PFJ | 2.83 | 8.02 | 8200 | 2540 | 29 | 406 |
| ZR36K3-PFJ | 3 | 8.61 | 8900 | 2730 | 29 | 406 |
| ZR36KH-PFJ | 3 | 8.61 | 8900 | 2730 | 29 | 406 |
| ZR42K3-PFJ | 3.5 | 9.94 | 15710 | 3140 | 30 | 419 |
| ZR47K3-PFJ | 3.92 | 11.02 | 11550 | 3460 | 32 | 436 |
| Three-Phase(380V-420V) | ||||||
| ZR28K3-TFD | 2.33 | 6.83 | 6900 | 2140 | 25 | 383 |
| ZR34K3-TFD | 2.83 | 8.02 | 8200 | 2500 | 28 | 406 |
| ZR34KH-TFD | 2.83 | 8.02 | 8200 | 2470 | 28 | 406 |
| ZR36K3-TFD | 3 | 8.61 | 8790 | 2680 | 29 | 406 |
| ZR36KH-TFD | 3 | 8.61 | 8300 | 2680 | 28 | 406 |
| ZR42K3-TFD | 3.5 | 9.94 | 15710 | 3100 | 28 | 419 |
| ZR47KC-TFD | 3.92 | 11.16 | 11550 | 2430 | 30 | 436 |
| VR61KF-TFP-542 | 5.08 | 14.37 | 14900 | 4636 | 28.5 | 436 |
| ZR61KC-TFD | 5.08 | 14.37 | 14600 | 4430 | 37 | 457 |
| ZR61KH-TFD | 5.08 | 14.37 | 14972 | 4440 | 35.9 | 457 |
| ZR68KC-TFD | 5.57 | 16.18 | 16900 | 4950 | 39 | 457 |
| ZR72KC-TFD | 6 | 17.06 | 17700 | 5200 | 39 | 457 |
| ZR81KC-TFD | 6.75 | 19.24 | 19900 | 5800 | 40 | 462 |
| Ā | ||||||
| VR94KS-TFP | 8 | 22.14 | 23300 | 6750 | 57 | 497 |
| VR108KS-TFP | 9 | 25.68 | 26400 | 7500 | 63 | 552 |
| VR125KS-TFP | 10 | 28.81 | 31000 | 9000 | 63 | 552 |
| VR144KS-TFP | 12 | 33.22 | 35000 | 15710 | 63 | 552 |
| VR160KS-TFP | 13 | 36.37 | 38400 | 11400 | 65 | 572 |
| VR190KS-TFP | 15 | 43.34 | 46300 | 13700 | 66 | 572 |
| ZR250KC-TWD | 20 | 56.57 | 60000 | 17700 | 142 | 736 |
| ZR310KC-TWD | 25 | 71.43 | 74000 | 22000 | 160 | 725 |
| ZR380KC-TWD | 30 | 57.5 | 92000 | 26900 | 176 | 725 |
| ZR81KC-TFD | 6.75 | 19.24 | 19900 | 5800 | 40 | 462 |
| Ā | ||||||
| VR94KS-TFP | 8 | 22.14 | 23300 | 6750 | 57 | 497 |
| VR108KS-TFP | 9 | 25.68 | 26400 | 7500 | 63 | 552 |
| VR125KS-TFP | 10 | 28.81 | 31000 | 9000 | 63 | 552 |
| VR144KS-TFP | 12 | 33.22 | 35000 | 15710 | 63 | 552 |
| VR160KS-TFP | 13 | 36.37 | 38400 | 11400 | 65 | 572 |
| VR190KS-TFP | 15 | 43.34 | 46300 | 13700 | 66 | 572 |
| Ā | ||||||
| ZR250KC-TWD | 20 | 56.57 | 60000 | 17700 | 142 | 736 |
| ZR310KC-TWD | 25 | 71.43 | 74000 | 22000 | 160 | 725 |
| ZR380KC-TWD | 30 | 57.5 | 92000 | 26900 | 176 | 725 |
Ā
| TECHNICAL DATA | |||||||
| Model | ZB15KQ | ZB19KQ | ZB21KQ | ZB26KQ | ZB29KQ | ZB38KQ | ZB45KQ |
| ZB15KQE | ZB19KQE | ZB21KQE | ZB26KQE | ZB29KQE | ZB38KQE | ZB45KQE | |
| Motor Type | TFD | TFD | TFD | TFD | TFD | TFD | TFD |
| PFJ | PFJ | PFJ | PFJ | PFJ | Ā | Ā | |
| Power(HP) | 2 | 2.5 | 3 | 3.5 | 4 | 5 | 6 |
| Displacement(m³/h) | 5.92 | 6.8 | 8.6 | 9.9 | 11.4 | 14.5 | 17.2 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Starting Current(LRA) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| TFD | 24.5-26 | 30-32 | 36-40 | 41-46 | 50 | 58.6-65.5 | 67-74 |
| PFJ | 53-58 | 56-61 | 75-82 | 89-97 | 113 | Ā | Ā |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Rated Load Current(RLA) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| TFD | 4.3 | 4.3 | 5.7 | 7.1 | 7.9 | 8.9 | 11.5 |
| PFJ | 11.4 | 12.9 | 16.4 | 18.9 | 19.3 | Ā | Ā |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Max. Operating Current(MCC) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| TFD | 6 | 6 | 8 | 10 | 11 | 12.5 | 16.1 |
| PFJ | 16 | 18 | 23 | 24 | 27 | Ā | Ā |
| Motor Run | 40μF/370V | 40μF/370V | 55μF/370V | 60μF/370V | 60μF/370V |  |  |
| Crankcase Heater Power(W) | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Size of Connecting Pipe(INCH) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Outer Diameter of Wxhaust Pipe | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
| Outer Diameter of Suction Pipe | 3/4 | 3/4 | 3/4 | 3/4 | 7/8 | 7/8 | 7/8 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Dimensions(MM) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Length | 242 | 242 | 243 | 243 | 242 | 242 | 242 |
| Width | 242 | 242 | 244 | 244 | 242 | 242 | 242 |
| Height | 383 | 383 | 412 | 425 | 430 | 457 | 457 |
| Foot Bottom Installation Dimensions(Aperture) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) |
| Fuel Injection(L) | 1.18 | 1.45 | 1.45 | 1.45 | 1.89 | 1.89 | 1.89 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Weight(KG) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Net.W | 23 | 25 | 27 | 28 | 37 | 38 | 40 |
| Gross.W | 26 | 29 | 30 | 31 | 40 | 41 | 44 |
Ā
| TECHNICAL DATA | |||||||
| Model | ZB48KQ | ZB58KQ | ZB66KQ | ZB76KQ | ZB88KQ | ZB95KQ | ZB114KQ |
| ZB48KQE | ZB58KQE | ZB66KQE | ZB76KQE | ||||
| Motor Type | TFD | TFD | TFD | TFD | TFD | TFD | TFD |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | |
| Power(HP) | 7 | 8 | 9 | 10 | 12 | 13 | 15 |
| Displacement(m³/h) | 18.8 | 22.1 | 25.7 | 28.8 | 38.2 | 36.4 | 43.4 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Starting Current(LRA) | 101 | 86-95 | 100-111 | 110-118 | 110-118 | 140 | 174 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Rated Load Current(RLA) | 12.1 | 16.4 | 17.3 | 19.2 | 22.1 | 22.1 | 27.1 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Max. Operating Current(MCC) | 17 | 23 | 24.2 | 26.9 | 31 | 31 | 39 |
| Crankcase Heater Power(W) | 70 | 90 | 90 | 90 | 90 | Ā | Ā |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Size of Connecting Pipe(INCH) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Outer Diameter of Wxhaust Pipe | 3/4 | 7/8 | 7/8 | 7/8 | 7/8 | 7/8 | 7/8 |
| Outer Diameter of Suction Pipe | 7/8 | 11/8 | 13/8 | 13/8 | 13/8 | 13/8 | 13/8 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Dimensions(MM) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Length | 242 | 263.6 | 263.6 | 263.6 | 263.6 | 242 | 264 |
| Width | 242 | 284.2 | 284.2 | 284.2 | 284.2 | 285 | 285 |
| Height | 457 | 477 | 546.1 | 546.1 | 546.1 | 522 | 553 |
| Foot Bottom Installation Dimensions(Aperture) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) |
| Fuel Injection(L) | 1.8 | 2.51 | 2.25 | 3.25 | 3.25 | 3.3 | 3.3 |
| Ā | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Weight(KG) | Ā | Ā | Ā | Ā | Ā | Ā | Ā |
| Net.W | 40 | 59.87 | 60.33 | 65.32 | 65.32 | 65 | 65 |
| Gross.W | 44 | Ā | Ā | Ā | Ā | Ā | Ā |
Archean refrigeration has been focusing on the refrigeration industry for more than 10 years. The compressors are sold all over the world and have been well received. The company has accumulated strong experience in the compressor market, rich technical support, and a satisfactory one-stop procurement solution. You can rest assured You don’t need to worry about this series, from placing an order to receiving the goods. We provide a complete solution to serve customers well, which is our purpose of hospitality.
Ā
/* March 10, 2571 17:59:20 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
| Installation Type: | Movable Type |
|---|---|
| Lubrication Style: | Lubricated |
| Cylinder Position: | Vertical |
| Model: | Zr36kce-Tfd-522 |
| Transport Package: | Wooden/Cartoon Box |
| Specification: | 26*26*58CM |
| Samples: |
US$ 100/Piece
1 Piece(Min.Order) | |
|---|
| Customization: |
Available
|
|
|---|
.webp)
Can Scroll Compressors Be Used in Residential Air Conditioning Units?
Yes, scroll compressors can be used in residential air conditioning units, and they are, in fact, a popular choice for such applications. Here’s a detailed explanation:
Scroll compressors are a type of positive displacement compressor that operates with a scroll or spiral-shaped design. They are known for their reliability, efficiency, and quiet operation, making them well-suited for residential air conditioning systems.
Here are some key reasons why scroll compressors are commonly used in residential air conditioning units:
1. Efficiency and Energy Savings:
Scroll compressors are highly efficient compared to other types of compressors, such as reciprocating compressors. They offer improved energy efficiency, which can result in lower energy consumption and reduced operating costs for homeowners. The scroll compressor’s design allows for smoother operation with fewer moving parts, resulting in reduced friction and improved overall efficiency.
2. Compact Size:
Residential air conditioning units typically have space limitations. Scroll compressors are known for their compact size and lightweight construction, making them easier to integrate into smaller air conditioning systems. Their compact design also helps reduce the overall size and footprint of the air conditioning unit, which can be beneficial for residential installations with limited space.
3. Quiet Operation:
Noise is a significant consideration for residential air conditioning units. Scroll compressors operate more quietly compared to reciprocating compressors. The scroll compressor’s design minimizes vibration and noise generation, resulting in a quieter overall operation. This can contribute to a more comfortable living environment for homeowners.
4. Reliability and Durability:
Scroll compressors are known for their reliability and durability. They have fewer moving parts compared to reciprocating compressors, reducing the likelihood of mechanical failure. The scroll design also helps minimize wear and tear, leading to longer compressor life and reduced maintenance requirements. This reliability is crucial for residential air conditioning systems, where homeowners rely on consistent and trouble-free cooling.
5. Improved Cooling Performance:
Scroll compressors offer enhanced cooling performance, providing better temperature control and humidity removal. They can handle varying load conditions efficiently, adjusting their capacity to match the cooling demands of the residential space. This results in improved comfort and more precise temperature control for homeowners.
6. Compatibility with Modern Refrigerants:
Scroll compressors are designed to work with a wide range of refrigerants, including the latest environmentally friendly and energy-efficient options. They can accommodate refrigerants such as R-410A, which is commonly used in residential air conditioning systems due to its superior performance and lower environmental impact compared to older refrigerants.
It’s important to note that there are various sizes and capacities of scroll compressors available to suit different residential air conditioning applications. The specific selection of a scroll compressor for a residential unit would depend on factors such as the cooling load requirements, size of the space being cooled, and the desired energy efficiency rating.
In summary, scroll compressors are well-suited for residential air conditioning units due to their efficiency, compact size, quiet operation, reliability, and improved cooling performance. Their utilization in residential applications contributes to energy savings, enhanced comfort, and reliable cooling for homeowners.
.webp)
What Industries Commonly Use Scroll Compressors?
Scroll compressors find application in various industries due to their unique characteristics and advantages. Here’s a detailed explanation:
1. HVAC (Heating, Ventilation, and Air Conditioning):
The HVAC industry extensively utilizes scroll compressors. Scroll compressors are commonly used in residential, commercial, and industrial HVAC systems for air conditioning, heat pumps, and refrigeration. Their efficiency, compact size, quiet operation, and reliability make them suitable for a wide range of HVAC applications.
2. Food and Beverage:
In the food and beverage industry, scroll compressors play a crucial role in refrigeration applications. They are used in refrigerated display cases, walk-in coolers, freezers, ice machines, and other refrigeration equipment. Scroll compressors are preferred for their ability to maintain consistent temperatures, energy efficiency, and low noise levels, making them ideal for preserving food quality and safety.
3. Medical and Pharmaceutical:
Scroll compressors are commonly employed in medical and pharmaceutical applications that require reliable and precise temperature control. They are used in medical refrigeration units, vaccine storage, laboratory equipment, pharmaceutical production processes, and cleanroom environments. The compact size, low vibration, and high efficiency of scroll compressors make them suitable for these critical applications.
4. Industrial Manufacturing:
Scroll compressors are utilized in various industrial manufacturing processes. They are employed in compressed air systems for applications such as pneumatic tools, air-operated machinery, and production lines. Scroll compressors are valued for their efficiency and reliability, providing a continuous supply of compressed air for industrial operations.
5. Automotive:
In the automotive industry, scroll compressors are commonly used in automotive air conditioning systems. They help provide efficient cooling and dehumidification for passenger comfort. Scroll compressors offer benefits such as reduced power consumption, compact size, and quiet operation, making them a preferred choice for automotive applications.
6. Data Centers and IT Cooling:
Scroll compressors are employed in data centers and IT cooling systems to maintain optimal temperatures and prevent equipment overheating. They are used in precision air conditioning units and chillers that provide cooling for server rooms and data processing facilities. The reliable operation, energy efficiency, and precise temperature control offered by scroll compressors are crucial for data center operations.
7. Laboratories and Research Facilities:
Scroll compressors are utilized in laboratories and research facilities for various applications. They are used in environmental chambers, climate control systems, refrigerated centrifuges, and other equipment requiring precise temperature and humidity control. Scroll compressors offer stable performance, low noise levels, and energy efficiency, making them suitable for laboratory settings.
8. Electronics Cooling:
In the electronics industry, scroll compressors are employed in cooling systems for electronic components and devices. They are used in air conditioning units for server rooms, computer rooms, telecommunications equipment, and electronic cabinets. Scroll compressors provide efficient cooling and contribute to maintaining the optimal operating conditions for sensitive electronic equipment.
9. Commercial Refrigeration:
Scroll compressors are widely used in commercial refrigeration applications, such as supermarkets, convenience stores, restaurants, and foodservice establishments. They are employed in refrigerated display cases, walk-in coolers, freezers, and ice cream machines. Scroll compressors offer energy efficiency, precise temperature control, and quiet operation, making them suitable for commercial refrigeration needs.
These are just a few examples of the industries that commonly utilize scroll compressors. The versatility, efficiency, compactness, reliability, and quiet operation of scroll compressors make them a preferred choice in various sectors where precise temperature control, refrigeration, and air conditioning are essential.
.webp)
Can Scroll Compressors Handle High-Pressure Applications?
Scroll compressors are capable of handling high-pressure applications, but there are certain considerations to keep in mind. Here’s a detailed explanation:
1. Pressure Ratings:
Scroll compressors are designed to operate within specific pressure ratings. The maximum pressure handling capacity of a scroll compressor is determined by its construction, materials, and design specifications. Manufacturers provide pressure ratings for their scroll compressors, indicating the maximum pressure at which the compressor can safely and reliably operate. It’s important to select a scroll compressor with a pressure rating suitable for the intended high-pressure application.
2. System Design:
The overall system design plays a crucial role in handling high-pressure applications. The components connected to the scroll compressor, such as the condenser, evaporator, and piping, should also be designed and rated to withstand the high pressures. Proper sizing, selection, and installation of these components are essential to ensure the safe and efficient operation of the entire system.
3. Refrigerant Type:
The choice of refrigerant used in the high-pressure application can impact the suitability of scroll compressors. Different refrigerants have varying pressure requirements and properties. It’s important to ensure that the scroll compressor is compatible with the specific refrigerant being used in the high-pressure system.
4. Cooling and Lubrication:
High-pressure applications can generate more heat, which may require enhanced cooling measures. Proper cooling mechanisms, such as fans or additional heat exchangers, should be incorporated into the system design to maintain the compressor’s operating temperature within acceptable limits. Additionally, adequate lubrication is crucial to minimize friction and wear at higher pressures. Ensuring the proper lubrication system is in place is essential for the reliable operation of scroll compressors in high-pressure applications.
5. Manufacturer Guidelines:
It’s important to consult the manufacturer’s guidelines and documentation for specific recommendations regarding the use of scroll compressors in high-pressure applications. Manufacturers provide detailed information on the maximum pressure ratings, refrigerant compatibility, cooling requirements, lubrication recommendations, and other important considerations specific to their scroll compressor models.
While scroll compressors can handle high-pressure applications, it’s critical to ensure that the compressor is appropriately selected, the system design is suitable, and all necessary precautions are taken to maintain safe and reliable operation. By following manufacturer guidelines and working with experienced HVAC professionals, scroll compressors can effectively handle high-pressure applications while maintaining their performance and longevity.


editor by CX 2024-01-10